Quicklub QLS 301 Grease Back Valve Remote Control 24 VDC (SSV6)
Lincoln® Quicklub QLS 301 For Grease Back Valve Remote Control SSV6 Valve Type
The QLS 301/311 for Remote Control allows customers to be in control of the lubrication process. The 24 VDC models monitor system cycling with a proximity switch. An external timer or PLC controls the interval between lube cycles. The 120 VAC models have no cycle monitoring and are on/off controlled by the users external timer or PLC. The minimum pause time requirements should be followed when setting up the external controller.Â
Installation kit comes with everything that’s needed for quick set-up. And both units come in versions for 6 12 or 18 lube points. Environmentally-friendly, with a built in safety valve and overfill protection.
- Compact pre-assembled pump and metering valve work with customer’s PLCs, no need for separate controller.
- Handle up to NLGI #2 grease for QLS 301
- Works between -10°F and 158°F allowing operation in many environments
Â
Model No. | P30131411110 |
Brand | Lincoln |
Operating Voltage | -24 VDC |
Operating Current | -24 VDC/1.0 A |
Operating Temperature | -10°F to 158°F/-25° to 70°C |
Number of Outlets | 6 |
Reservoir Capacity | 61″/1.0L |
Protection | NEMA 4 |
Minimum Pause Time | 4 min. DC models |
Maximum Operating Time | 25 min. DC models |
Timer Memory | Indefinite |
Maximum Operating Pressure | Grease: 3000 psi/205 bar Oil: 1160 psi/80 bar |
Output per Outlet & Cycle | approx. 0.012″/approx. 0.2 cm. |
Lubricant | up to NLGI 2 grease |
Weight | 15 lb. |